FLP-12,5 V/1S+1
pluggable module, visual fault signalling, module locking, remote fault signalling
- combination of varistor lightning current arrester and encapsulated efficiency spark gap, connected in the 1+1 mode
- installation at the boundary of zones LPZ 0 and LPZ 1 or higher, for objects in LPL III and IV
- for protection against impact of partial lightning currents, induced overvoltages during a lightning strike or switching overvoltages
Technical parameters
| Parameter name | Parameter value |
| Type of SPD | T1,T2 |
| Mounting | DIN rail 35 mm |
| Nominal voltage | 230 V AC |
| Maximum operating voltage L-N | 275.00 V AC |
| Maximum operating voltage N-PE | 255.00 V AC |
| Type of network | TT |
| Maximum overcurrent protection | 160 A gL/gG |
| Short-circuit current rating | 50.0 kA |
| Total discharge current (10/350 µs) | 25.00 kA |
| Lightning impulse current (10/350 µs) L-N | 12.50 kA |
| Lightning impulse current (10/350 µs) N-PE | 25.00 kA |
| Nominal discharge current (8/20 µs) L-N | 30.00 kA |
| Nominal discharge current (8/20 µs) N-PE | 30.00 kA |
| Maximum discharge current (8/20 µs) L-N | 60.00 kA |
| Maximum discharge current (8/20 µs) N-PE | 60.00 kA |
| Voltage protection level mode L-N | 1.50 kV |
| Voltage protection level mode L-PE | 1.50 kV |
| Voltage protection level mode N-PE | 1.50 kV |
| Voltage protection level at 5 kA L-N | 0.90 kV |
| Ability to independently switch off the following current N-PE | 100.0 kA |
| Response time L-N | 25 ns |
| Response time N-PE | 100 ns |
| TOV 5 s L-N | 335 V |
| TOV characteristic (TOV 5 s) | withstand |
| TOV 200 ms N-PE | 1 200 V |
| TOV characteristic (TOV 200 ms) | withstand |
| Cross-section of connected conductors solid (min) | 1.00 mm2 |
| Cross-section of connected conductors solid (max) | 35.00 mm2 |
| Cross-section of connected conductors stranded (min) | 1.00 mm2 |
| Cross-section of connected conductors stranded (max) | 25.00 mm2 |
| Cross-section of remote indication conductors solid (max) | 1.5 mm2 |
| Cross-section of remote indication conductors stranded (max) | 1.5 mm2 |
| Fault indication L-N | red indication field |
| Remote indication | potential-free change-over contact |
| Remote indication contacts | 250V/0,5A AC,250V/0,1A DC |
| Degree of protection | IP 20 |
| Range of ambient temperatures (min/max) | -40 / 80 °C |
| Humidity | 5 – 95 % |
| According to standard | EN 61643-11:2012, IEC 61643-11:2011 |
| ETIM Class | EC001457 |
| Plug module | FLP-12,5 V/0|FLP-NPE 25 V/0 |
| EAN | 8595090534242 |
| Customs tariff number | 85363090 |