วันจันทร์ - วันเสาร์ 8:00 น. - 17:00 น.

📞 📞

• 16 and 32-channel digital input modules
• For flexible adaptation of the controller to the corresponding
task
• For subsequent expansion of the system with additional inputs
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific
information was added.

Ordering dataArticle No.
SIPLUS SM 521 digital input modules
(Extended temperature range and exposure to environmental substances)
16 inputs, 24 V DC, isolated, parameterizable diagnostics and hardware interrupts6AG1521-1BH00-7AB0
32 inputs, 24 V DC, isolated, parameterizable diagnostics and hardware interrupts6AG1521-1BL00-7AB0
16 inputs, 24 V DC, isolated, input delay 3.2 ms6AG1521-1BH50-7AB0
16 inputs, 230 V AC, isolated, input delay 20 ms6AG1521-1FH00-7AB0
16 inputs, 48 … 125 V UC, input delay 0.05 … 20 ms, parameterizable diagnostics and hardware interrupts6AG1521-7EH00-7AB0
Accessories
SIPLUS S7-1500 U connector6AG1590-0AA00-7AA0
Spare part for connecting I/O modules; self-assembling backplane bus; 5 pieces per packaging unit;
with conformal coating, -40…+70 °C
Other accessories
See SIMATIC S7-1500, SM 521 digital input modules, page 4/173
รายการ6AG1521-1BH00-7AB0 / 6ES7521-1BH00-0AB06AG1521-1BL00-7AB0 / 6ES7521-1BL00-0AB06AG1521-1BH50-7AB0 / 6ES7521-1BH50-0AB06AG1521-1FH00-7AB0 / 6ES7521-1FH00-0AB06AG1521-7EH00-7AB0 / 6ES7521-7EH00-0AB0
Based onSIPLUS S7-1500 DI 16x24VDC HFSIPLUS S7-1500 DI 32x24VDC HFSIPLUS S7-1500 DI 16x24VDC SRC BASIPLUS S7-1500 DI 16x230VAC BASIPLUS S7-1500 DI 48VUC/125VDC HF
Ambient temperature during operation
– horizontal installation, min.-40 °C = Tmin (incl. condensation/frost)-40 °C = Tmin (incl. condensation/frost)-40 °C = Tmin (incl. condensation/frost)-40 °C = Tmin (incl. condensation/frost)-40 °C = Tmin (incl. condensation/frost)
– horizontal installation, max.70 °C = Tmax70 °C = Tmax
+60 °C: max. 16 inputs
70 °C = Tmax
+60 °C: max. 16 inputs
70 °C = Tmaxsee Derating BasedOn
– vertical installation, min.-40 °C = Tmin-40 °C = Tmin-40 °C = Tmin-40 °C = Tmin-40 °C = Tmin
– vertical installation, max.70 °C = Tmax70 °C = Tmax70 °C = Tmax70 °C = Tmax70 °C = Tmax
Altitude during operation relating to sea level
– Installation altitude max.5,000 m5,000 m5,000 m2,000 m2,000 m
– Ambient air temp–pressure-altitudeTmin … Tmax at 1140 hPa … 795 hPa
(–1 000 m … +2 000 m)
Tmin … Tmax at 1140 hPa … 795 hPa
(–1 000 m … +2 000 m)
Tmin … Tmax at 1140 hPa … 795 hPa
(–1 000 m … +2 000 m)
Tmin … Tmax at 1140 hPa … 795 hPa
(–1 000 m … +2 000 m)
Tmin … Tmax at 1140 hPa … 795 hPa
(–1 000 m … +2 000 m)
– Derating (ความสามารถลดลงเมื่อสูงขึ้น)Tmax – (Tmax × 20 K) at 658 hPa = 540 hPa
(+2 000 m … +5 000 m)
Tmax – (Tmax × 20 K) at 658 hPa = 540 hPa
(+2 000 m … +5 000 m)
Tmax – (Tmax × 20 K) at 658 hPa = 540 hPa
(+2 000 m … +5 000 m)
Tmax – (Tmax × 20 K) at 658 hPa = 540 hPa
(+2 000 m … +5 000 m)
Tmax – (Tmax × 20 K) at 658 hPa = 540 hPa
(+2 000 m … +5 000 m)
รายการ6AG1521-1BH00-7AB0 / 6ES7521-1BH00-0AB06AG1521-1BL00-7AB0 / 6ES7521-1BL00-0AB06AG1521-1BH50-7AB0 / 6ES7521-1BH50-0AB06AG1521-1FH00-7AB0 / 6ES7521-1FH00-0AB06AG1521-7EH00-7AB0 / 6ES7521-7EH00-0AB0
Relative humidity
• With condensation, tested in accordance with IEC 60068-2-38, max.100 % RH incl. condensation/frost100 % RH incl. condensation/frost100 % RH incl. condensation/frost100 % RH incl. condensation/frost100 % RH incl. condensation/frost
(no commissioning in bedewed state), horizontal only
Resistance
Coolants and lubricantsYes; incl. diesel and oil dropletsYes; incl. diesel and oil dropletsYes; incl. diesel and oil dropletsYes; incl. diesel and oil dropletsYes; incl. diesel and oil droplets
Use in stationary industrial systems
– to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungi, dry rot spores
(w/o fauna); Class 3B3 on request
Yes; Class 3B2 mold, fungi, dry rot spores
(w/o fauna); Class 3B3 on request
Yes; Class 3B2 mold, fungi, dry rot spores
(w/o fauna); Class 3B3 on request
Yes; Class 3B2 mold, fungi, dry rot spores
(w/o fauna); Class 3B3 on request
Yes; Class 3B2 mold, fungi, dry rot spores
(w/o fauna); Class 3B3 on request
– to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 *³ (severity 3)Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 *³ (severity 3)Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 *³ (severity 3)Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 *³ (severity 3)Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 *³ (severity 3)
– to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust *¹Yes; Class 3S4 incl. sand, dust *¹Yes; Class 3S4 incl. sand, dust *¹Yes; Class 3S4 incl. sand, dust *¹Yes; Class 3S4 incl. sand, dust *¹
Use on ships/at sea
– to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (no fauna); Class 6B3 on requestYes; Class 6B2 mold and fungal spores (no fauna); Class 6B3 on requestYes; Class 6B2 mold and fungal spores (no fauna); Class 6B3 on requestYes; Class 6B2 mold and fungal spores (no fauna); Class 6B3 on requestYes; Class 6B2 mold and fungal spores (no fauna); Class 6B3 on request
– to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 *³ (severity 3)Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 *³ (severity 3)Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 *³ (severity 3)Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 *³ (severity 3)Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 *³ (severity 3)
– to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust *¹Yes; Class 6S3 incl. sand, dust *¹Yes; Class 6S3 incl. sand, dust *¹Yes; Class 6S3 incl. sand, dust *¹Yes; Class 6S3 incl. sand, dust *¹

ติดต่อสอบถามเพิ่มเติม

โทรติดต่อ

085-838-2423
085-150-5506
062-381-5341

อีเมล

sale@enscigroup.com

เปิดทำการ

จันทร์ - เสาร์
08.00 - 17.00 น.

สอบถามผ่าน Social Media

“SIPLUS SM 521 โมดูลอินพุตดิจิทัล Siemens S7-1500 สำหรับงานอุตสาหกรรมหนัก รองรับแรงดัน 24V / 230V AC/DC”