วันจันทร์ - วันเสาร์ 8:00 น. - 17:00 น.

📞 📞

SIPLUS SB 1231 RTD รหัสสินค้า 6AG1231-5PA30-5XB0


 

โมดูล SIPLUS SB 1231 RTD รองรับเซนเซอร์ Pt100/Pt200/Pt500/Pt1000 พร้อมความละเอียด 15-bit + sign ใช้งานร่วมกับ Siemens S7-1200 ทนสภาพแวดล้อมหนัก รองรับการใช้งานอุตสาหกรรม

Overview
• For the convenient recording of temperatures with great
accuracy
• 1 input with 16-bit resolution
• Common resistance-type temperature detectors can be used
• Can easily be retrofitted to existing plant
• Can be plugged directly into the CPU
Note:
SIPLUS extreme products are based on SIMATIC standard
products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific
information was added.

 

Ordering data Article No.
SIPLUS SB 1231 RTD
signal board
(Extended temperature range
and exposure to environmental
substances)
1 input for resistance temperature
sensors Pt 100, Pt 200, Pt 500,
Pt 1000, resolution 15-bit + sign
6AG1231-5PA30-5XB0
Accessories See SIMATIC S7-1200
SB 1231 RTD signal board,
page 3/107

 

Technical specifications
Article number
Based on
6AG1231-5PA30-5XB0
6ES7231-5PA30-0XB0
SIPLUS S7-1200 SB 1231 1AI RTD
Article number
Based on
6AG1231-5PA30-5XB0
6ES7231-5PA30-0XB0
SIPLUS S7-1200 SB 1231 1AI RTD
Ambient temperature during
operation
Use on ships/at sea
– to biologically active substances
according to EN 60721-3-6- to chemically active substances
according to EN 60721-3-6
– to mechanically active sub
stances
according to EN 60721-3-6
Usage in industrial process
technology
– Against chemically active
substances acc. to EN 60654-4
– Environmental conditions for
process, measuring and control
systems acc. to ANSI/ISA-71.04
Remark

– Note regarding classification of
environmental conditions acc. to
EN 60721, EN 60654-4 and
ANSI/ISA-71.04

Yes; Class 6B2 mold and fungal
spores (excluding fauna);
Class 6B3 on request
Yes; Class 6C3 (RH < 75 %) incl.
salt spray acc. to EN 60068-2-52
(severity degree 3); *
Yes; Class 6S3 incl. sand, dust; *

Yes; Class 3 (excluding
trichlorethylene)
Yes; Level GX group A/B (excluding
trichlorethylene; harmful gas
concentrations up to
the limits of EN 60721-3-3
class 3C4 permissible); level LC3
(salt spray) and level LB3 (oil)

* The supplied plug covers must
remain in place over the unused
interfaces during operation!

• min.
• max
Conformal coating
ㆍCoatings for printed circuit board
assemblies acc. to EN 61086
ㆍ Protection against fouling acc. to
EN 60664-3
ㆍ Military testing according to
MIL-I-46058C, Amendment 7
ㆍQualification and Performance of
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
Altitude during operation relating to
sea level
• Installation altitude above sea level,
max.
• Ambient air temperature-barometric
pressure-altitude

5 000 m

Tmin … Tmax at
1 140 hPa … 795 hPa
(-10000 m … +2 000 m) //
Tmin … (Tmax – 10 K) at
795 hPa … 658 hPa
(+20000 m … m.. +3 500 m) //
Tmin … (Tmax -20 K) at
658 hPa … 540 hPa
(+3 500 m … +5 000 m)

Relative humidity
ㆍ With condensation, tested in
accordance with IEC 60068-2-38,
max.
100 %; RH incl. condensation / frost
(no commissioning in bedewed
state), horizontal installation
Resistance
Coolants and lubricants
– Resistant to commercially
available coolants and lubricants
Use in stationary industrial systems
– to biologically active substances
according to EN 60721-3-3
– to chemically active substances
according to EN 60721-3-3
– to mechanically active substances
according to EN 60721-3-3
Yes; Incl. diesel and oil droplets in
the air
Yes; Class 3B2 mold, fungus and dry
rot spores (with the exception of
fauna); Class 3B3 on request
Yes; Class 3C4 (RH < 75 %) incl.
salt spray acc. to EN 60068-2-52
(severity degree 3); *
Yes; Class 3S4 incl. sand, dust, “

 

สินค้าที่เกี่ยวข้อง

ติดต่อสอบถามเพิ่มเติม

โทรติดต่อ

085-838-2423
085-150-5506
062-381-5341

อีเมล

sale@enscigroup.com

เปิดทำการ

จันทร์ - เสาร์
08.00 - 17.00 น.

สอบถามผ่าน Social Media

SIPLUS SB 1231 RTD โมดูลรับสัญญาณอุณหภูมิแบบ RTD สำหรับ Siemens S7-1200 รุ่น 6AG1231-5PA30-5XB0