SIPLUS SM 1278 4xIO-Link Master

 

ㆍ Module for connecting up to 4 IO-Link devices according to

IO-Link Specification V1.1. The IO-Link parameters are

configured using the Port Configuration Tool (PCT),

Version V3.2 and higher.

Note:

SIPLUS extreme products are based on SIMATIC standard

products. The contents listed here were taken from the

respective standard products. SIPLUS extreme-specic

information was added.

 

 

Ordering data Article No.
SIPLUS SM 1278
4xlO-Link Master signal module
(Extended temperature range
and exposure to environmental
substances)
ㆍ For areas with exceptional
exposure to environmental
substances (conformal coating)
6AG1278-4BD32-4XB0
ㆍ -25 … +70 “C,from +60 … +70 *C
number of simultaneously
controllable inputs and outputs
max. 50%
6AG1278-4BD32-2XB0
Technical specifications
Article number
Based on
6AG1278-4BD32-2XB0
6ES7278-4BD32-0XB0
SIPLUS S7-1200 SM 1278 IO-Link Master
6AG1278-4BD32-4XB0
6ES7278-4BD32-0XB0
SIPLUS S7-1200 SM 1278 IO-Link Master
Ambient conditions
Ambient temperature during
operation
ㆍmin.
ㆍmax.
ㆍ At cold restart, min.
-40 “C; = Tmin (incl. condensation/frost); start-up -25 “C
’70 *C; = Tmax
‘-25 *C
-20 “C; = Tmin (incl. condensation/frost), start-up @ 0 “C
60 *C; = Tmax
0 *C
Altitude during operation relating to
sea level
ㆍ Installation altitude above sea level,
max.
5 000 m 5 000 m
ㆍ Ambient air temperature-barometric
pressure-altitude
Tmin … Tmax at 1 140 hPa … 795 hPa
(-10000 m … +2 000 m) //
Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa
(+2 000 m … +3 500 m) //
Tmin … (Tmax -20 K) at 658 hPa … 540 hPa
(+3 500 m … +5 000 m)
Tmin … Tmax at 1 140 hPa … 795 hPa
(-10000 m … +2 000 m) //
Tmin … (Tmax – 10 K) at 795 hPa … 658 hPa
(+2 000 m … +3 500 m) //
Tmin … (Tmax -20 K) at 658 hPa … 540 hPa
(+3 500 m … +5 000 m)
Relative humidity
With condensation, tested in
accordance with IEC 60068-2-38,
max.
100 %; RH incl. condensation/frost (no commissioning
under condensation conditions)
100 %; RH incl. condensation/frost (no commissioning
under condensation conditions)
Resistance
Coolants and lubricants
– Resistant to commercially
available coolants and lubricants
Yes; Incl. diesel and oil droplets in the air Yes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
– to biologically active substances
according to EN 60721-3-3
– to chemically active substances
according to EN 60721-3-3
– to mechanically active substances
according to EN 60721-3-3
Yes; Class 382 mold, fungus and dry rot spores
(with the exception of fauna); Class 3B3 on request
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
EN 60068-2-52 (severity degree 3); *
Yes; Class 3S4 incl. sand, dust, *
Yes; Class 382 mold, fungus and dry rot spores
(with the exception of fauna); Class 3B3 on request
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to
EN 60068-2-52 (severity degree 3); *
Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
– to biologically active substances
according to EN 60721-3-6
– to chemically active substances
according to EN 60721-3-6
– to mechanically active substances
according to EN 60721-3-6
Yes; Class 682 mold and fungal spores (excluding fauna);
Class 6B3 on request
Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
EN 60068-2-52 (severity degree 3); *
Yes; Class 6S3 incl. sand, dust; *
Yes; Class 682 mold and fungal spores (excluding fauna);
Class 6B3 on request
Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to
EN 60068-2-52 (severity degree 3); *
Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process
technology
– Against chemically active
substances acc. to EN 60654-4
‘- Environmental conditions for
process, measuring and control
systems acc. to ANSI/ISA-71.04
Yes; Class 3 (excluding trichlorethylene)

Yes; Level GX group A/B (excluding trichlorethylene;
harmful gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 (oil)

Yes; Class 3 (excluding trichlorethylene)

Yes; Level GX group A/B (excluding trichlorethylene;
harmful gas concentrations up to the limits of
EN 60721-3-3 class 3C4 permissible);
level LC3 (salt spray) and level LB3 (oil)

Remark
– Note regarding classification of
environmental conditions acc. to
EN 60721, EN 60654-4 and
ANSI/ISA-71.04
* The supplied plug covers must remain in place over the
unused interfaces during operation!
* The supplied plug covers must remain in place over the
unused interfaces during operation!
Conformal coating
ㆍ Coatings for printed circuit board
assemblies acc. to EN 61086
ㆍ Protection against fouling acc. to
EN 60664-3
ㆍ Military testing according to
MIL-I-46058C, Amendment 7
ㆍ Qualification and Performance of
Electrical Insulating Compound for
Printed Board Assemblies
according to IPC-CC-830A
Yes; Class 2 for high reliability

Yes; Type 1 protection

Yes; Discoloration of coating possible during service life

Yes; Conformal coating, Class A

Yes; Class 2 for high reliability

Yes; Type 1 protection

Yes; Discoloration of coating possible during service life

Yes; Conformal coating, Class A