SIMATIC S7-1200 Basic Controllers
CM 1242-5
The CM 1242-5 communications module is used to connect
a SIMATIC S7-1200 to PROFIBUS as a DP slave and has the
following characteristics:
• PROFIBUS DPV1 slave in accordance with IEC 61158
• Module replacement without PG supported
• Power is supplied via the backplane bus so that no extra
cabling is required
• Support of all standard baud rates from 9.6 kbps to 12 Mbps
• Compact industry-standard enclosure in S7-1200 design for
mounting on a DIN rail
• Fast commissioning thanks to easy configuration using
STEP 7 without additional programming overhead
The CM 1242-5 is intended for use in factory automation.
Low-cost PROFIBUS-based automation solutions can be
created on the basis of the SIMATIC S7-1200 for optimal
production.
CM 1242-5
| Ordering data | Article No. |
| CM 1242-5 communications moduleCommunications module for electrical connection of SIMATIC S7-1200 to PROFIBUS as a DP slave module |
6GK7242-5DX30-0XE0 |
|
PROFIBUS FastConnect With 90° cable outlet; |
6ES7972-0BA52-0XA0 6ES7972-0BB52-0XA0 |
|
PROFIBUS FC standard cable 2-core bus cable, shielded, |
6XV1830-0EH10 |
|
PROFIBUS FastConnect Stripping tool for fast stripping of |
6GK1905-6AA00 |
|
PROFIBUS bus terminal 12M Bus terminal for connection of |
6GK1500-0AA10 |
| Technical specifications | ||||
| Article number product type designation |
6GK7242-5DX30-0XE0 CM 1242-5 |
Article number product type designation |
6GK7242-5DX30-0XE0 CM 1242-5 |
|
| transfer rate | product features, product functions, product components general |
|||
| transfer rate • at the 1st interface according to PROFIBUS |
9.6 kbit/s … 12 Mbit/s | number of units • per CPU maximum |
3 | |
| interfaces | performance data PROFIBUS DP | |||
| number of interfaces according to Industrial Ethernet 0 number of electrical connections • at the 1st interface according to PROFIBUS 1 • for power supply 0 type of electrical connection • at the 1st interface according to PROFIBUS |
0
1 0 9-pin Sub-D socket (RS485) |
service as DP slave • DPV0 • DPV1 data volume • of the address range of the inputs as DP slave total • of the address range of the outputs as DP slave total |
Yes Yes 240 byte 240 byte |
|
| supply voltage, current consumption, power loss |
performance data telecontrol | |||
| type of voltage of the supply voltage DC supply voltage 1 from backplane bus 5 V consumed current • from backplane bus at at typical power loss [W] |
DC 5V0.15 A 0.75 W |
protocol is supported • TCP/IP |
No | |
| ambient conditions | product functions management, configuration, engineering |
|||
| ambient temperature • for vertical installation during operation • for horizontally arranged busbars during operation • during storage • during transport relative humidity • at 25 °C without condensation during operation maximum protection class IP |
0 … 45 *C
0 … 55 *C -40 … +70 *C 95.1% IP20 |
configuration software • required |
STEP 7 Basic/Professional | |
| design, dimensions and weights | standards, specifications, approvals hazardous environments |
|||
| module format
width |
Compact module S7-1200 single width 30 mm 100 mm 75 mm 0.115 kgYes No Yes |
certificate of suitability CCC for hazardous zone according to GB standard Yes; GB3836.1, GB3836.8 certificate of suitability CCC for hazardous zone according to GB standard as marking |
Yes; GB3836.1, GB3836.8
Ex nA IIC T4 Gc |
|
| standards, specifications, approvals Environmental Product Declaration |
||||
| Environmental Product Declaration Global Warming Potential [CO2 eq] • total • during manufacturing • during operation • after end of life |
Yes89.58 kg 14.29 kg 75.11 kg 0.18 kg |
|||
| further information internet links | ||||
| internet link • to website: Image database |
https://www.automation.siemens.com/bilddb |
|||
| • to website: Industry Online Support | https://support.industry.siemens.com | |||