SIEMENS 3MH7,3MU7 & 3MV8

contactors, overload relays & motor starter protectors

 

 

Selection & ordering data

Accessories

Product No. of
auxiliary
contacts
Compatible
contactor
Maximum
mountable
auxiliary
switches
Article no.
NO NC
1-pole & 2-pole
front auxiliary
switches 

2 Size
0, 1, 2, 3, 4
1 3MH7920-0CT10
1 1 3MH7920-0CT10
2 3MH7920-0CT10
4-pole front
auxiliary switches
4 3MH7940-0CT10
3 1 3MH7931-0CT10
2 2 3MH7922-0CT10
1 3 3MH7913-0CT10
4 3MH7904-0CT10
Lateral auxiliary
switches#
2 2 3MH7920-0CL10
1 1 3MH7911-0CL10
1 1 Size
5, 6, 7, 8
2 3MH79110CL21
2 3MH79110CL22

Note:
#Compatible with 3MT7 3-pole power contactor only

 

Surge suppressor
Compatible with SINOVA 3MT7 3-pole power contactors
Product
image 
Voltage  Mounting position  Article no.
Surge suppressor 24-48V AC 50/60Hz Between
A1-A2 coil
terminals
3MT7900-1SC21
110-240V AC 50/60Hz 3MT7900-1SL21
380-440V AC 50/60Hz 3MT7900-1SV21

 

Selection & ordering data

Accessories

Pneumatic timer
Compatible with 3MT7 3-pole power contactors Size 0, 1, 2, 3, 4
Product
image
No. of
auxiliary
contacts
Function  Timing  Article no. 
NO  NC  Seconds
ON delay
pneumatic timer
1 1 ON delay 0.1-3 3MT7900-0PN10
0.1-30 3MT7900-0PN20
10-180 3MT7900-0PN30
OFF delay
pneumatic timer
OFF delay 0.1-3 3MT7900-0PF10
0.1-30 3MT7900-0PF20
10-180 3MT7900-0PF30

 

Interlock
For 3MT7 3-pole power contactors
Mechanical interlock

 

Suitable for contactors Size 0, 1, 2 3MT7900-1XM01 Suitable for contactor Size 3 3MT7900-1XM02 Suitable for contactor Size 4 3MT7900-1XM03
Electro-mechanical
interlock 
3MT7900-1XE01 3MT7900-1XE02 3MT7900-1XE03

 

Mechanical Interlock
For 3MT7 3-pole power contactors
Product image  Contactor  Article no. 
Mechanical
interlock
Size 5 3MT7900-1XM04
Size 6 3MT7900-1XM05
Size 7 3MT7900-1XM06
Size 8 3MT7900-1XM07
Size 5 / Size 6 3MT7900-1XM45
Size 6 / Size 7 3MT7900-1XM56
Type  Overload relay size  Article no.
Relay stand-alone
installation kit
1 3MU7900-0MA10
2 3MU7900-0MA20
3 3MU7900-0MA30

Note: Accessories shown are only applicable to 3MU71, 3MU72 and 3MU73.

 

Selection & ordering data

3MU7 thermal overload relays

Size  Trip
class
Rated
power
three
phase
motor at
400V
Current
setting
value
Short circuit
protection
with fuse,
type of
coordination
“2″
(operational
class gG)
Suitable
for
contactor
size
Article
no.
kW  A
1

Class 10 0.04 0.10-0.16 2 0, 1, 2 3MU7110-0AA0
Class 10 0.06 0.16-0.25 2 0, 1, 2 3MU7110-0BA0
Class 10 0.09 0.25-0.40 2 0, 1, 2 3MU7110-0CA0
Class 10 0.18 0.40-0.63 2 0, 1, 2 3MU7110-0DA0
Class 10 0.25 0.63-1 4 0, 1, 2 3MU7110-0EA0
Class 10 0.55 1-1.6 4 0, 1, 2 3MU7110-0FA0
Class 10 0.75 1.25-2 6 0, 1, 2 3MU7110-0GA0
Class 10 0.75 1.6-2.5 6 0, 1, 2 3MU7110-0HA0
Class 10 1.5 2.5-4 10 0, 1, 2 3MU7110-0JA0
Class 10 2.2 4-6 16 0, 1, 2 3MU7110-0KA0
Class 10 3 5.5-8 20 0, 1, 2 3MU7110-0LA0
Class 10 4 7-10 20 0, 1, 2 3MU7110-0MA0
Class 10 5.5 9-13 25 0, 1, 2 3MU7110-0NA0
Class 10 7.5 12-18 32 1, 2 3MU7110-0PA0
Class 10 11 17-25 50 1, 2 3MU7110-0QA0
2

Class 10 15 23-32 63 2 3MU7210-1AA0
Class 10 18.5 28-36 63 2 3MU7210-1BA0
3

Class 10 15 23-32 63 3, 4 3MU7310-2AA0
Class 10 18.5 30-40 80 3, 4 3MU7310-2BA0
Class 10 22 37-50 80 3, 4 3MU7310-2CA0
Class 10 30 48-65 80 3, 4 3MU7310-2DA0
Class 10 37 55-70 125 4 3MU7310-2EA0
Class 10 37 63-80 125 4 3MU7310-2FA0
Class 10 45 80-93 125 4 3MU7310-2GA0
4

Class 10A 85-135A 224 Screw mounting 3MU7410-3AA1
Class 10A 115-180A 250 Screw mounting 3MU7410-3BA1
Class 10A 160-250A 355 Screw mounting 3MU7410-3CA1
Class 10A 200-320A 400 Screw mounting 3MU7410-3DA1
Class 10A 250-400A 500 Screw mounting 3MU7410-3EA1
5

Class 10A 312-500A 500 Screw mounting 3MU7510-4AA1

 

Selection & ordering data

3MV81 motor starter protectors
Product Image Rated
current
Motor
power
Current
setting for
thermal
overload
Instantaneous
trip
Without Auxiliary Contact  With Auxiliary Contact
(1NO+1NC)
Article no.  Article no. 
(A)  (kW)  (A)  (A)
3MV8100-0..00

0.16 0.04 0.11 ~ 0.16 1.9 3MV8100-0MB00 3MV8100-1MB00
0.24 0.06 0.16 ~ 0.24 2.9 3MV8100-0MC00 3MV8100-1MC00
0.4 0.09/0.12 0.24 ~ 0.4 4.8 3MV8100-0MD00 3MV8100-1MD00
0.6 0.12/0.18 0.4 ~ 0.6 7.2 3MV8100-0ME00 3MV8100-1ME00
1 0.25 0.6 ~ 1 12 3MV8100-0MF00 3MV8100-1MF00
1.6 0.37/0.55 1 ~ 1.6 19 3MV8100-0MG00 3MV8100-1MG00
2.4 0.75 1.6 ~ 2.4 29 3MV8100-0MH00 3MV8100-1MH00
3.2 1.1 2 ~ 3.2 38 3MV8100-0NH00 3MV8100-1NH00
4 1.1/1.5 2.4 ~ 4 48 3MV8100-0MJ00 3MV8100-1MJ00
5 1.5/2.2 3.2 ~ 5 60 3MV8100-0NJ00 3MV8100-1NJ00
6 2.2 4 ~ 6 72 3MV8100-0MK00 3MV8100-1MK00
8 3 5 ~ 8 96 3MV8100-0NK00 3MV8100-1NK00
10 3/4 6 ~ 10 120 3MV8100-0ML00 3MV8100-1ML00
13 4/5.5 8 ~ 13 156 3MV8100-0NL00 3MV8100-1NL00
16 7.5 10 ~ 16 190 3MV8100-0MM00 3MV8100-1MM00
20 7.5 14 ~ 20 240 3MV8100-0MN00 3MV8100-1MN00
25 11 18 ~ 25 300 3MV8100-0MP00 3MV8100-1MP00

 

3MV82 motor starter protectors
Product Image Rated
current
Motor
power
Current
setting for
thermal
overload
Instantaneous
trip
Without Auxiliary Contact  With Auxiliary Contact
(1NO+1NC)
Article no.  Article no. 
(A)  (kW)  (A)  (A)
3MV8200-1..00 

1.6 0.37/0.55 1 ~ 1.6 19 3MV8200-0MG00 3MV8200-1MG00
2.4 0.75 1.6 ~ 2.4 29 3MV8200-0MH00 3MV8200-1MH00
4 1.1/1.5 2.4 ~ 4 48 3MV8200-0MJ00 3MV8200-1MJ00
6 2.2 4 ~ 6 72 3MV8200-0MK00 3MV8200-1MK00
10 3/4 6 ~ 10 120 3MV8200-0ML00 3MV8200-1ML00
16 5.5/7.5 10 ~ 16 190 3MV8200-0MM00 3MV8200-1MM00
25 11 16 ~ 25 300 3MV8200-0MN00 3MV8200-1MN00
32 15 22 ~ 32 380 3MV8200-0MP00 3MV8200-1MP00
40 18.5 28 ~ 40 480 3MV8200-0MQ00 3MV8200-1MQ00
52 22 36 ~ 52 600 3MV8200-0MR00 3MV8200-1MR00

 

Accessories
Type  Product Image  Suitable for  Mounting  Auxiliary contacts  Article no. 
Auxiliary contact 3MV81 / 3MV82 Right side 1NO+1NC 3MV9131-3AA00
Short circuit fault indicator 3MV81 / 3MV82 Right side 1NO+1NC 3MV9131-7AA00
Undervoltage release  3MV81 / 3MV82 Left side AC230V 50Hz 3MV9132-0AB15
Undervoltage release with
lead action auxiliary contacts 
3MV81 / 3MV82 Left side AC230V 50Hz 3MV9132-0AB35
Shunt release  3MV81 / 3MV82 Left side AC230V 50Hz 3MV9132-0AB55

Note:

(1) Auxiliary contacts and short circuit fault indicators can be installed on the right side of the circuit breakers at the same time (the short circuit fault indicators are installed on the inside frst, and the auxiliary contacts are installed on the outside). It is also possible to install only one auxiliary contact or only one short circuit fault indicator.

(2) Undervoltage release, undervoltage release with advance action auxiliary contact, and shunt release are all installed on the left side of the circuit breakers, but only one of the three can be installed at a time.

 

Selection table 400V AC

Direct On- Line (DOL) StarterMotor starter protector

+ contactor

+ thermal overload relay

 

Motor details Motor Starter
Protector
Instantaneous
trip (A) 
Contactor  Contactor rating  Thermal
Overload
Setting
range
Overload
release
Motor
Power (P)
Motor
current (I)
kW  Article no.  Article no.  A
0.37 1.1 3MV8100-0MG00 19 3MT7006-0AA10-0AP0 6 3MU7110-0FA0 1-1.6
0.55 1.5 3MV8100-0MG00 19 3MT7006-0AA10-0AP0 6 3MU7110-0GA0 1.25-2
0.75 1.9 3MV8100-0MH00 29 3MT7006-0AA10-0AP0 6 3MU7110-0HA0 1.6-2.5
1.1 2.7 3MV8100-0NH00 38 3MT7006-0AA10-0AP0 6 3MU7110-0JA0 2.5-4
1.5 3.6 3MV8100-0MJ00 48 3MT7006-0AA10-0AP0 6 3MU7110-0JA0 2.5-4
2.2 5 3MV8100-0NJ00 60 3MT7010-0AA10-0AP0 9 3MU7110-0KA0 4-6
3 6.5 3MV8200-0ML00 120 3MT7010-0AA10-0AP0 9 3MU7110-0LA0 5.5-8
3.7 7.8 3MV8200-0ML00 120 3MT7012-0AA10-0AP0 12 3MU7110-0MA0 7-10
4 8.5 3MV8200-0ML00 120 3MT7012-0AA10-0AP0 12 3MU7110-0MA0 7-10
5.5 11.5 3MV8200-0MM00 190 3MT7018-1AA10-0AP0 18 3MU7110-0NA0 9-13
7.5 15.5 3MV8200-0MM00 190 3MT7025-2AA10-0AP0 25 3MU7110-0PA0 12-18
11 22 3MV8200-0MN00 300 3MT7038-2AA10-0AP0 38 3MU7110-0QA0 17-25
15 29 3MV8200-0MP00 380 3MT7038-2AA10-0AP0 38 3MU7210-1AA0 23-32
18.5 35 3MV8200-0MQ00 480 3MT7050-3AA11-0AP0 50 3MU7310-2BA0 30-40
22 41 3MV8200-0MR00 600 3MT7065-3AA11-0AP0 65 3MU7310-2CA0 37-50

 

Start delta starter Motor starter protector
 + star (wye)-delta starting
+ thermal overload relay

Motor Rating Motor Starter
Protector
Instantaneous
trip (A) 
Contactor Line  Contactor Delta  Contactor rating  Contactor Star  Contactor rating  Overload relay  Setting range
Overload
release
Timer
Motor
Power
(P)
IL (A)
kW  Article no.  Article no.  Article no.  Article no.  A Article no. Article no.
5.5 11.5 3MV8200-0MM00 190 3MT7038-2AA10-0AP0 3MT7038-2AA10-0AP0 38 3MT7006-0AA10-0AP0 6 3MU7110-0LA0 5.5-8 3RP25
7.5 15.5 3MV8200-0MM00 190 3MT7038-2AA10-0AP0 3MT7038-2AA10-0AP0 38 3MT7006-0AA10-0AP0 6 3MU7110-0MA0 7-10 3RP25
11 22 3MV8200-0MN00 300 3MT7038-2AA10-0AP0 3MT7038-2AA10-0AP0 38 3MT7010-0AA10-0AP0 9 3MU7110-0NA0 9-13 3RP25
15 29 3MV8200-0MP00 380 3MT7050-3AA11-0AP0 3MT7050-3AA11-0AP0 50 3MT7012-0AA10-0AP0 12 3MU7110-0PA0 12-18 3RP25
18.5 35 3MV8200-0MQ00 480 3MT7050-3AA11-0AP0 3MT7050-3AA11-0AP0 50 3MT7018-1AA10-0AP0 18 3MU7110-0QA0 17-25 3RP25
22 41 3MV8200-0MR00 600 3MT7065-3AA11-0AP0 3MT7065-3AA11-0AP0 65 3MT7018-1AA10-0AP0 18 3MU7210-1AA0 23-32 3RP25

 

 

 