วันจันทร์ - วันเสาร์ 8:00 น. - 17:00 น.

📞 📞

LC1G115KUEN

รายละเอียด

TeSys Giga high power contactor, 3 poles (3 NO) suitable for category AC-3 applications up to 115A 75kW@440V, equipped with 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliable 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 500 cycles per hour and environments up to 60°C. It’s built with high reliability delivering mechanical durability up to 8 million cycles. Contact Wear Diagnosis (CWD) is a standard function, It continuously monitors and provide feedback through healthy and alarm conditions by an LED indicator. It is possible to replace switching module (main contacts), control module enhancing contactor life with simple maintenance activities. Front accessible main power connections are with bolted connection and control connections by push-in terminals for easy and quick assembly. It provides IP2x protection from front face with optional terminal shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, with no derating up to 3000m altitude. Contactor can be installed in three quadrants of vertical plane, and OLR could be directly mounted below contactor. The dimensions are 193mm x 108mm x 193mm (H x W x D), compact size enables panel space savings. Multi standards certified (CB, CCC, cULcs, CE, UKCA marking,CE) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.

ข้อมูลจำเพาะ

RangeTeSys
Range of productTeSys Giga
Product or component typeContactor
Device short nameLC1G
Contactor applicationPower switching
Motor control
Utilisation categoryAC-1
AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8a
AC-8b
DC-1
DC-3
DC-5
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current250 A (at <40 °C) at <= 1000 V AC-1
115 A (at <60 °C) at <= 440 V AC-3
[Uc] control circuit voltage100…250 V AC 50/60 Hz
100…250 V DC
Control circuit voltage limitsOperational: 0.8 Uc Min…1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C)
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current250 A (at 40 °C)
Rated breaking capacity1040 A at 440 V
[Icw] rated short-time withstand current1.1 kA – 10 s
0.64 kA – 30 s
0.52 kA – 1 min
0.4 kA – 3 min
0.32 kA – 10 min
Associated fuse rating125 A aM at <= 440 V for motor
125 A aM at <= 690 V for motor
315 A gG at <= 690 V
Average impedance0.00018 Ohm
[Ui] rated insulation voltage1000 V
Power dissipation per pole10 W AC-1 – Ith 250 A
3 W AC-3 – Ith 115 A
Compatibility codeLC1G
Pole contact composition3 NO
Auxiliary contact composition1 NO + 1 NC
Motor power kW30 kW at 230 V AC 50/60 Hz (AC-3e)
55 kW at 400 V AC 50/60 Hz (AC-3e)
55 kW at 415 V AC 50/60 Hz (AC-3e)
75 kW at 440 V AC 50/60 Hz (AC-3e)
75 kW at 500 V AC 50/60 Hz (AC-3e)
75 kW at 690 V AC 50/60 Hz (AC-3e)
30 kW at 230 V AC 50/60 Hz (AC-3)
55 kW at 400 V AC 50/60 Hz (AC-3)
55 kW at 415 V AC 50/60 Hz (AC-3)
75 kW at 440 V AC 50/60 Hz (AC-3)
75 kW at 500 V AC 50/60 Hz (AC-3)
75 kW at 690 V AC 50/60 Hz (AC-3)
30 kW at 230 V AC 50/60 Hz (AC-4)
55 kW at 400 V AC 50/60 Hz (AC-4)
55 kW at 415 V AC 50/60 Hz (AC-4)
65 kW at 440 V AC 50/60 Hz (AC-4)
65 kW at 500 V AC 50/60 Hz (AC-4)
75 kW at 690 V AC 50/60 Hz (AC-4)
Motor power hp30 hp at 200/208 V 60 Hz
40 hp at 230/240 V 60 Hz
75 hp at 460/480 V 60 Hz
100 hp at 575/600 V 60 Hz
Irms rated making capacity1560 A at 440 V
Coil technologyBuilt-in bidirectional peak limiting
Safety reliability levelB10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability8 Mcycles
inrush power in VA (50/60 Hz, AC)540 VA
inrush power in W (DC)380 W
hold-in power consumption in VA (50/60 Hz, AC)12.4 VA
hold-in power consumption in W (DC)7.8 W
Operating time40…70 ms closing
15…50 ms opening
Maximum operating rate600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
150 cyc/h AC-4
Connections – terminalsPower circuit: bar 2 – busbar cross section: 25 x 6 mm
Power circuit: lugs-ring terminals 1 185 mm²
Power circuit: bolted connection
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end
Connection pitch35 mm
Mounting supportPlate
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-1
UL 60335-2-40:Annex JJ
Product certificationsCB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque18 N.m
Height193 mm
Width108 mm
Depth193 mm
Net weight3.5 kg
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-60…80 °C
Mechanical robustnessVibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
ColourDark grey
Protective treatmentTH
Permissible ambient air temperature around the device-40…70 °C at Uc
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height25.500 cm
Package 1 Width18.500 cm
Package 1 Length32.000 cm
Package 1 Weight4.512 kg
Unit Type of Package 2S06
Number of Units in Package 212
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight66.008 kg