วันจันทร์ - วันเสาร์ 8:00 น. - 17:00 น.

📞 📞

หมวดหมู่

SCHNEIDER Circuit breaker frame, MasterPacT MTZ2 16N1, for MicroLogic Active, 1600A, 42kA/440VAC 50/60Hz (Icu), 3P, drawout

 

Description
“This device is a breaker frame for MasterPacT MTZ with Micrologic Active last generation of high current air circuit breakers.” “MasterPacT MTZ2 16N1 is a 3 poles breaker frame in drawout version.” “The rated current is 1600A.” “The breaking capacity (Icu) is 42kA rms at 440VAC 50/60Hz.” “This breaker frame must be associated with the corresponding chassis which has to be ordered separately.” “This breaker frame is compatible with MicroLogic Active control unit which has also to be ordered separately.” “MasterPacT MTZ Active combines real-time information and ease of use to enable fast mitigation of outage events.” “MasterPacT MTZ Active is designed to achieve new levels of uptime and agility.” “MicroLogic Active control units embeds features for protection, measurement, communication, maintenance and diagnosis.” “The dimensions are 441mm (W) x 439mm (H) x 403mm (D), the weight is approximately 90kg.” “MasterPacT MTZ Active is compliant with international standards IEC 60947-1 and IEC 60947-2.” “MasterPacT MTZ Active circuit breakers are part of the Active Panel solution made possible by Schneider Electric’s EcoStruxure Power architecture.” “Green packaging eliminates single-use plastics and features 100% recycled and recyclable cardboard.” “Transformer efficiency data helps inform actions to save energy and reduce CO2 emissions.”
Main
Range MasterPacT
Product name MasterPacT MTZ2 Active
Product or component type Circuit breaker
Device short name MTZ2 16 N1
Device application Power distribution protection
Poles description 3P
Control unit Without control unit
Product compatibility control unit MicroLogic Active 1.0 E
control unit MicroLogic Active 1.0 EP
control unit MicroLogic Active 2.0 A
control unit MicroLogic Active 2.0 AP
control unit MicroLogic Active 2.0 E
control unit MicroLogic Active 2.0 EP
control unit MicroLogic Active 5.0 A
control unit MicroLogic Active 5.0 AP
control unit MicroLogic Active 5.0 E
control unit MicroLogic Active 5.0 EP
control unit MicroLogic Active 6.0 A
control unit MicroLogic Active 6.0 AP
control unit MicroLogic Active 6.0 E
control unit MicroLogic Active 6.0 EP
[In] rated current 1600 A at 40 °C
Performance type N1 42 kA 440 V AC
[Ue] rated operational voltage 690 V AC 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Selectivity category Category B
Control type Push-button
Mounting mode Drawout
Complementary
[Icu] rated ultimate short-circuit breaking capacity 42 kA at 220/415 V AC 50/60 Hz
42 kA at 440 V AC 50/60 Hz
42 kA at 525 V AC 50/60 Hz
42 kA at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity 42 kA at 220/415 V AC 50/60 Hz
42 kA at 440 V AC 50/60 Hz
42 kA at 525 V AC 50/60 Hz
42 kA at 690 V AC 50/60 Hz
[Icw] rated short-time withstand current 42 kA 0.5 s
42 kA 1 s
22 kA 3 s
[Icm] rated short-circuit making capacity 88 kA 220/415 V AC at 50/60 Hz
88 kA 440 V AC at 50/60 Hz
88 kA 525 V AC at 50/60 Hz
88 kA 690 V AC at 50/60 Hz
Sensor rating 800 A
1000 A
1250 A
1600 A
[Ui] rated insulation voltage 1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 12 kV
Power dissipation in W 480 W
Power dissipation per pole 160 W
Maximum breaking time 25 ms
Maximum closing response time 70 ms
Mounting support Base plate
Rails
Upside connection Front
Rear
Downside connection Front
Rear
Connection pitch 115 mm
Mechanical durability 25000 cycles with maintenance
Electrical durability 10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Height (H) Drawout circuit breaker with chassis: 439 mm
Drawout circuit breaker without chassis: 301 mm
Width (W) Drawout circuit breaker with chassis: 441 mm
Drawout circuit breaker without chassis: 378 mm
Depth (D) Drawout circuit breaker with chassis: 403 mm
Drawout circuit breaker without chassis: 331 mm
Net weight 90 kg
Standards EN/IEC 60947-1
EN/IEC 60947-2
Product certifications CE
CCC
EAC
Environment
IP degree of protection IP3X conforming to EN/IEC 60529
IK degree of protection IK07 conforming to EN 50102
Pollution degree 3 conforming to IEC 60664-1
Ambient air temperature for operation -25…70 °C
Temperature derating table 40 °C ( 1600 A )
45 °C ( 1600 A )
50 °C ( 1600 A )
55 °C ( 1600 A )
60 °C ( 1600 A )
65 °C ( 1600 A )
70 °C ( 1520 A )
Ambient air temperature for storage -40…85 °C
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2 cm
Package 1 Width 1 cm
Package 1 Length 2 cm
Package 1 Weight 10 g
Contractual warranty
Warranty (in months) 18

ติดต่อสอบถามเพิ่มเติม

โทรติดต่อ

085-838-2423
085-150-5506
062-381-5341

อีเมล

sale@enscigroup.com

เปิดทำการ

จันทร์ - เสาร์
08.00 - 17.00 น.

สอบถามผ่าน Social Media

SCHNEIDER Circuit breaker frame, MasterPacT MTZ2 16N1, for MicroLogic Active, 1600A, 42kA/440VAC 50/60Hz (Icu), 3P, drawout