Power Factor Correction
Selection & ordering data
Standard Cap 3-phase
Rate Voltage | Output | Capacity | StandardCap | ||
in KVAr | |||||
50Hz | in µF | Dimensions | weight | Ordercode | Ordercode MLFB |
3 x | D xH (mm.) | kg. | |||
400 V AC | 15 | 99.5 | 75 x 275 | 1.4 | 4RB7150-3EA50 |
20 | 132.5 | 85 x 275 | 1.8 | 4RB7200-3EA50 | |
25 | 166 | 85 x 350 | 2.2 | 4RB7250-3EA50 | |
415 V AC | 15 | 92 | 75 x 275 | 1.5 | 4RB7150-3EB50 |
20 | 123 | 85 x 275 | 1.7 | 4RB7200-3EB50 | |
25 | 166 | 85 x 350 | 2.2 | 4RB7250-3EB50 | |
30 | 154 | 96 x 350 | 2.7 | 4RB7300-3EB50 | |
440 V AC | 15 | 82 | 75 x 275 | 1.4 | 4RB7150-3EE50 |
20.8 | 114 | 85 x 275 | 1.7 | 4RB7208-3EE50 | |
25 | 137 | 85 x 350 | 2.2 | 4RB7250-3EE50 | |
30 | 164 | 96 x 350 | 2.7 | 4RB7300-3EE50 | |
525 V AC | 20.8 | 80 | 85 x 350 | 2.2 | 4RB7208-3FC50 |
25 | 96 | 85 x 350 | 2.2 | 4RB7250-3FC50 | |
30 | 115 | 96 x 350 | 2.7 | 4RB7300-3FC50 |
Premium Cap 3-phase
Rate Voltage | Output in KVAr |
Capacity | Premium Cap | |||
50Hz | in µF 3 x |
Dimensions D xH (mm.) |
weight kg. |
Ordercode MLFB |
Unit Price (THB) |
|
400 V AC | 15 | 100 | 85 x 218 | 1.2 | 4RB8150-3EA10 | |
20 | 133 | 100 x 224 | 1.7 | 4RB8200-3EA10 | ||
25 | 165 | 116 x 192 | 1.9 | 4RB8250-3EA10 | ||
Premium Cap Heavy Duty | ||||||
40 | 265 | 136 x 233 | 3.7 | 4RB8400-3EA20 | ||
50 | 332 | 136 x 312 | 5.0 | 4RB8500-3EA20 | ||
415 V AC | 15 | 93 | 85 x 200 | 1.1 | 4RB8150-3EB10 | |
20 | 124 | 100 x 207 | 1.6 | 4RB8208-3EB10 | ||
25 | 154 | 116 x 192 | 1.9 | 4RB8250-3EB10 | ||
440 V AC | 15 | 83 | 85 x 218 | 1.2 | 4RB8150-3EE10 | |
20 | 110 | 100 x 207 | 1.6 | 4RB8200-3EE10 | ||
25 | 137 | 116 x 192 | 1.9 | 4RB8250-3EE10 | ||
30 | 165 | 125 x 192 | 2.3 | 4RB8300-3EE10* | ||
Premium Cap Heavy Duty |
||||||
40 | 219 | 136 x 217 | 136 x 217 | 3.7 | 4RB8400-3EE20 | |
50 | 274 | 136 x 279 | 136 x 279 | 4.5 | 4RB8500-3EE20 | |
525 V AC | 15 | 58 | 85 x 218 | 1.2 | 4RB8150-3FC10 | |
20 | 77 | 100 x 224 | 100 x 224 | 1.7 | 4RB8200-3FC10 | |
25 | 97 | 116 x 207 | 116 x 207 | 2.1 | 4RB8250-3FC10 | |
30 | 116 | 125 x 207 | 125 x 207 | 2.4 | 4RB8300-3FC10** | |
Premium Cap Heavy Duty | ||||||
40 | 154 | 136×233 | 3.7 | 4RB8400-3FC20 | ||
800 V AC | 15 | 25 | 100 x 224 | 2.1 | 4RB8150-3JA20 | |
20 | 33 | 116 x 224 | 2.8 | 4RB8200-3JA20 | ||
25 | 41 | 116 x 224 | 2.8 | 4RB8250-3JA20 |
Automatic Power Factor Correction Relay (APFC relay)
Features
• Easy accessibility of parameters
• Universal control supply–optimizing the no of variants
• Automatic/ Linear/ Rotational switching modes of banks
• Selectable 1A/ 5A current input
• LCD version with RS485 Communication MODBUS RTU Protocol
• Confrms to IEC 60947-5-1, carry CE and RoHS Compliant
Capacitor Duty Contactors
Capacitor kvar 440V, 3Ph, 50Hz | Built-in aux. contacts | Article No. | |
2.5kVAr | 1NO | 3MT70002JA106AN2 | |
1NC | 3MT70002JA016AN2 | ||
5kVAr | 1NO | 3MT70005JA106AN2 | |
1NC | 3MT70005JA016AN2 | ||
7.5kVAr | 1NO+1NC | 3MT70007JA116AN2 | |
2NC | 3MT70007JA026AN2 | ||
10kVAr | 1NO+1NC | 3MT70010JA116AN2 | |
2NC | 3MT70010JA026AN2 | ||
12.5kVAr | 1NO+1NC | 3MT70012JA116AN2 | |
2NC | 3MT70012JA026AN2 | ||
16.7kVAr | 1NO+1NC | 3MT70016JA116AN2 | |
2NC | 3MT70016JA026AN2 | ||
20kVAr | 1NO+1NC | 3MT70020JA116AN2 | |
2NC | 3MT70020JA026AN2 | ||
25kVAr | 1NO+1NC | 3MT70025JA116AN2 | |
2NC | 3MT70025JA026AN2 | ||
33.3kVAr | 1NO+2NC | 3MT70033JA126AN2 | |
40kVAr | 1NO+2NC | 3MT70040JA126AN2 | |
50kVAr | 1NO+2NC | 3MT70050JA126AN2 | |
60kVAr | 1NO+2NC | 3MT70060JA126AN2 | |
75kVAr | 1NO+2NC | 3MT70075JA126AN2 | |
80kVAr | 1NO+2NC | 3MT70080JA126AM0 | |
100kVAr | 1NO+2NC | 3MT70100JA126AM0 |
Operation
Siemens 3MT7 capacitor duty contactors
are specially designed to meet stringent
requirements of capacitor switching as
deliberated above. These contactors are
make auxiliary contact in series with quick
discharge damping six-resistors-2 per
phase to limit peak current to value within
contactor making capacity. The damping
resistors are activated via early make
auxiliary contacts before the main contacts
close. During switching, after attenuation
of the peak current, they are decoupled
again.
HRC Fuses
LV HRC fuse systems are used for installation systems in
non-residential, commercial and industrial buildings as well as
in switchboard assemblies of power utilities. They therefore
protect essential building parts and systems.
The components and auxiliary equipment are designed in
such a way as to ensure the safe replacement of LV HRC fuse
systems or isolation of systems.
LV HRC fuse links are available in the sizes 000, 00, 0, 1, 2, 3, 4
and 4a.
Benefits
LV HRC fuse links with combination front indicator the tripping
of a fuse. This enables identification and replacement of the
tripped fuse links. This increases system availability.
LV HRC fuse links are always equipped with silver-plated
contact pins. This means that they are non-corroding and have
less contact resistance. This ensures the long-term operational
safety of the plant.