TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides magnetic protection, breaking capacity Icu 25kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).อ่านน้อยลง

Tripping Curves for GV4L and GV4LE Combined with Thermal Overload Relay LRD or LR9

Average Operating Times at 20 °C Related to Multiples of the Setting Current

GV4L02 and GV4LE02 to 12 with LRD05 to LRD14, GV4L80 and GV4LE80 with LRD3363

13 poles from cold state

22 poles from cold state

33 poles from hot state

46…14 Ir

AThermal overload relay protection zone

BGV4L protection zone

GV4L25 and GV4LE25 with LRD 318, LRD325 GV4L50 AND GV4LE50 with LRD 332, LRD 340, LRD 350

13 poles from cold state

22 poles from cold state

33 poles from hot state

46…14 Ir

AThermal overload relay protection zone

BGV4L protection zone

GV4L115 and GV4LE115 with Class 10 LR9F5367, LR9D5369 and Class 20 LR9D5567, LR9F5569

1old state curve

2Hot state curve

36…14 Ir

Current Limitation on Short-Circuit for GV4L, GV4LE (3-Phase 400/415 V) Dynamic Stress

I peak = f (prospective Isc) at 1.05 Ue = 435 V

1Maximum peak current

2GV4L115

3GV4L80

4GV4L50

5GV4L25

6GV4L12

7GV4L07

8GV4L03

9GV4L02

Current Limitation on Short-Circuit for GV4L, GV4LE + Thermal Overload Relay LRD or LR9 (3-Phase 400/415 V) Dynamic Stress

I peak = f (prospective Isc) at 1.05 Ue = 435 V

1Maximum peak current

2GV4L115 + LR9D5367 or LR9F5367

3GV4L80 + LRD3361

4GV4L50 + LRD340

5GV4L25 + LRD325

6GV4L12 + LRD313

7GV4L07 + LRD12

8GV4L03 + LRD07

9GV4L02 + LRD07

Thermal Limit on Short-Circuit for GV4L, GV4LE

Thermal Limit in A2s

Sum of I2dt = f (prospective Isc) at 1.05 Ue = 435 V

1GV4L115

2GV4L80

3GV4L50

4GV4L25

5GV4L12

6GV4L07

7GV4L03

8GV4L02

Current Limitation on Short-Circuit for GV4L, GV4LE + Thermal Overload Relay LRD or LR9

Thermal Limit in kA in the Magnetic Operating Zone

Sum of I2dt = f (prospective Isc) at 1.05 Ue = 435 V

1.GV4L115 + LR9D5367 or LR9F5367

2.GV4L80 + LRD3361

3.GV4L50 + LRD340

4.GV4L25 + LRD325

5.GV4L12 + LRD313

6.GV4L07+ LRD12

7.GV4L03+ LRD07

8.GV4L02 + LRD07

GV4 with Toggle: GV4LE, GV4PE, GV4PEM

With EverLink® Connector

With Crimp Lug Connector

(1)Interphases barriers

(2)Long terminal shield

GV4 with Rotary Handle: GV4L, GV4P, or GV4LE, GV4PE, GV4PEM with GV4ADN01, GV4ADN02 Direct Mounting Rotary Handle

Dimensions

GV4L, GV4P, GV4LE, GV4PE, GV4PEM

Panel Mounting with M4 Screws

Door Cut-Out for Rotary Handle

Minimum Safety Clearance

Toggle-type, rotary handle-type: identical clearance values.