Fluke a3000 FC,a3001 FC,a3002 FC

Fluke a3000 FC Wireless AC Current Clamp Meter
A fully functional true-rms current clamp meter that wirelessly relays
measurements to other Fluke Connect™ enabled master units, listed
below

  • Measure up to 400 A ac
  • Logging function for recording and saving up to 65,000 readings
  • Use as a standalone meter or as part of the system
  • Inrush function

Fluke a3001 FC Wireless iFlex AC
Current Meter

A true-rms current clamp meter that wirelessly relays
measurements to other Fluke Connect™ enabled
master units, listed below.

  • Measure up to 2500 A ac
  • Logging function for recording and saving up to 65,000 readings
  • Use as a standalone meter or as part of the system
  • Inrush function

Fluke a3002 FC Wireless AC/DC
Current Meter Module

Designed to be used with the i410 or i1010 ac/dc current clamps (not included with
meter). AC/DC current meter that wirelessly relays measurements from the i410 or i1010
clamp accessory to other Fluke Connect™ enabled master units, listed below.

  • Measure up to 400 A ac or 400 A dc with i410 (sold separately)
  • Measure up to 600 A ac or 1000 A dc with i1010 (sold separately)
  • Use as a standalone meter or as part of the system
Specificationsa3000 FCa3001 FCa3002 FC
Range0.5A to 400.0 A AC0.5 A to 2500 A ACup to 600A AC and 1000 A DC (with I1010 Current Clamp)
Resolution0.1 A0.1 A0.1 A
Accuracy400.0 A: 2 % ± 5 digits (10 Hz to 100 Hz), 2.5 % ± 5 digits
(100 Hz to 500 Hz)
3 % ± 5 digits (5 Hz to 500 Hz)AC:1.0%+3
DC:0.5%+3
(45Hz to 1000Hz)
InrushMax displayed reading: 999.9A
Crest Factor (50Hz/60Hz)3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 % for C.F. > 23.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
LCD w/backlight3½ digits3½ digits3 ½ digits, 6000 counts, 4/sec update rate
Log rate/interval1 sec minimum/adjustable by PC or front panel1 sec minimum/adjustable by PC or front panel1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR62 AA, NEDA 15 A, IEC LR62 AA, NEDA 15 A, IEC LR6
RF communications2.4 GHZ ISM Band2.4 GHZ ISM Band2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Temperature coefficientAdd 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)Add 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)Add 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Operating humidity90 % at 35 °C
75 % at 40 °C
45 % at 50 °C
90 % at 35 °C
75 % at 40 °C
45 % at 50 °C
90 % at 35 °C
75 % at 40 °C
45 % at 50 °C
EMCEN 61326-1:2013EN 61326-1:2013EN 61326-1:2013
Safety complianceIEC 61010-1, CAT III 600 V, CAT IV 300 V, 3rd editionIEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd editionIEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd edition
Safety ratingCAT III 600 VCAT IV 600 V, CAT III 1000 VCAT IV 600 V, CAT III 1000 V
CertificationscCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLEcCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLEcCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP30IP42IP42
Jaw opening34 mm (1.33 in)25.4 cm (10 in) coil
Size (HxWxD)20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in)16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)160 mm x 66 mm x 38 mm (6.3 in x 2.6 in x 1.5 in)